期刊论文详细信息
Sensors
Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device
Daniel Bachmann1  Frank Weichert1 
[1] Department of Computer Science VII, Technical University Dortmund, Dortmund 44221, Germany; E-Mails:
关键词: Leap Motion Controller;    Fitts' law;    human-computer interaction;   
DOI  :  10.3390/s150100214
来源: mdpi
PDF
【 摘 要 】

This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 % for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.

【 授权许可】

CC BY   
© 2015 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190018158ZK.pdf 20992KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:26次