期刊论文详细信息
Energies
Active Power Filtering Using the ZDPC Method under Unbalanced and Distorted Grid Voltage Conditions
Kamel Djazia1  Fateh Krim1  Abdelmadjid Chaoui1  Mustapha Sarra1 
[1] Power Electronics and Industrial Control Laboratory, University of Sétif1, Sétif 19000, Algeria
关键词: Shunt Active Power Filter (SAPF);    Direct Power Control (DPC);    Zero Direct Power Control (ZDPC);    harmonic;    instantaneous active power;   
DOI  :  10.3390/en8031584
来源: mdpi
PDF
【 摘 要 】

In this paper, we propose a new Zero Direct Power Control (ZDPC) technique for active compensation of harmonics and reactive power, using shunt active power filter (SAPF), based on cancellation of instantaneous active and reactive power disturbances by comparison with their zero references. To separate harmonic and fundamental components of the line voltage and current a highly selective filter (HSF) has been used. Depending on the power errors and line voltage vector position, a switching table produces the appropriate control vectors leading to the active and reactive power variation required to reach the zero power references, even under grid voltage unbalanced and distorted conditions. The experimental validation of the proposed ZDPC has been performed. The results are compared to other recent techniques to demonstrate the superiority and feasibility of the proposed strategy.

【 授权许可】

CC BY   
© 2015 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190015800ZK.pdf 2314KB PDF download