期刊论文详细信息
Sensors
Using K-Nearest Neighbor Classification to Diagnose Abnormal Lung Sounds
Chin-Hsing Chen2  Wen-Tzeng Huang3  Tan-Hsu Tan1  Cheng-Chun Chang1  Yuan-Jen Chang2 
[1] Department of Electrical Engineering, National Taipei University of Technology, Taipei 10608, Taiwan, China; E-Mails:;Department of Management Information Systems, Central Taiwan University of Science and Technology, Taichung 40601, Taiwan, China; E-Mail:;Department of Computer Science and Information Engineering, Minghsin University of Science and Technology, Hsinchu 30401, Taiwan, China; E-Mail:
关键词: K-means algorithm;    K-nearest neighbor;    lung sound;    MFCC;    stethoscope;   
DOI  :  10.3390/s150613132
来源: mdpi
PDF
【 摘 要 】

A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician’s subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

【 授权许可】

CC BY   
© 2015 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190011518ZK.pdf 1695KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:11次