期刊论文详细信息
Chemical and biochemical engineering quarterly
Application of a New Potentiometric Sensor for Determination of Anionic Surfactants in Wastewater
S. Petrušić1  O. Galović1  M. . Samardžić1  M. Sak-Bosnar1 
关键词: anionic surfactant;    screen-printed;    microsensor;    potentiometric;    wastewater;   
DOI  :  10.15255/CABEQ.2014.2164
来源: Croatian Society of Chemical Engineers
PDF
【 摘 要 】

Abstract A new screen-printed potentiometric microsensor (SPMS) for the determination of anionic surfactants (ASs) based on the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion pair as a sensing material was applied to real industrial effluents. The sensor is accurate, inexpensive, simple and very sensitive. The solutions of cetylpyridinium chloride (CPC) of the concentrations down to 5· 10–5 mol dm–3 were used as a titrant. Standard addition method was used for checking the precision and accuracy of measurements providing satisfactory results with recoveries between 98.3 to 102.0 % in pure AS solutions and 99.0 to 114.5 % in wastewater. Standard spectrophotometric method Methylene Blue Active Substances (MBAS) was used as control for comparison of the results obtained with the new sensor. The results obtained using SPMS were compared with those obtained by the polymeric membrane ion-selective electrodes (ISEs), containing the same sensing material, and exhibited good mutual agreement.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912090769306ZK.pdf 1502KB PDF download
  文献评价指标  
  下载次数:68次 浏览次数:16次