期刊论文详细信息
Chemical and biochemical engineering quarterly
Mass Transfer At Helical Coils In Bubble Columns
M. M. Mohamed1  S. A. Nosier1 
关键词: Mass transfer;    Bubble columns;    solid-liquid;    helical coil;    diffusion controlled;    gas sparging;   
DOI  :  
来源: Croatian Society of Chemical Engineers
PDF
【 摘 要 】

Abstract Mass transfer rates at the outer surfaces of helical coil were studied by measuring the rate of diffusion-controlled dissolution of a helical copper coil in acidified chromate solution. Variables studied were; air superficial velocity, solution temperature and the number of active rings per coil. The mass transfer coefficient was found to increase with increasing airflow rate. Increasing the number of active rings per coil decrease the mass transfer coefficient. The mass transfer data were correlated by the equation: J = 0.778 (Fr ⋅ Re)–0.263 (dt/lw)0.245

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912090768691ZK.pdf 163KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:10次