References(33)Cited-By(3)Accelerated ageing was conducted on UHMWPE with and without vitamin E (D, L-α tocopherol, VE). Wear performance was investigated using a knee simulator and wear debris was analysed. Aged UHMWPE with VE showed significantly lower wear volume than that of aged virgin UHMWPE and showed approximately similar wear volume as non-aged virgin UHMWPE. There were no significant differences among the materials as far as shape factor of the debris is concerned.