Biaxial Tensile Properties of Thoracic Aortic Aneurysm Tissues
Kiichiro KUMAGAI2  Naoko IKUTA1  Toshiro OHASHI3  Hiroji AKIMOTO2  Masaaki SATO3  Tomohiro FUKUI3  Koichi TABAYASHI2  Takeo MATSUMOTO3  Toshihiro TANAKA3 
[1] Biomechanics Laboratory, Department of Mechanical Engineering, Nagoya Institute of Technology;Department of Thoracic and Cardiovascular Surgery, Graduate School of Medicine, Tohoku University;Biomechanics Laboratory, Graduate School of Mechanical Engineering, Tohoku University
关键词: True Aneurysm;    Dissecting Aneurysm;    Annulo Aortic Ectasia;    Post-Stenotic Dilatation;    Marfan's Syndrome;    Mechanical Properties;    Tensile Test;    Anisotropy;    Elastic Modulus;   
DOI  :  10.1299/jbse.4.518
来源: Japan Society of Mechanical Engineers
PDF
【 摘 要 】

References(18)Cited-By(15)Mechanical properties of human aortic aneurysm tissues were measured with a biaxial tensile tester. Fifteen-mm-square specimens were obtained from thoracic aortic aneurysms of various origins and from undilated aortas adjacent to the aneurysms during aneurysmectomy, and were stored frozen until the measurement. Each specimen was stretched biaxially in physiological saline at room temperature at the rate of ∼0.2 mm/sec. Although the ordered displacement was set equal for both directions, real strain applied to the specimens was not equibiaxial. The stress-strain curves under equibiaxial stretch were obtained by fitting measured curves with a strain energy function considering material anisotropy. Effects of freezing and ambient temperature on the mechanical properties were evaluated with porcine thoracic aortas. The mechanical properties of the frozen-stored specimens at 23°C were almost similar to those of the fresh specimens at 37 °C. Elastic modulus at zero load averaged for both directions Hmi = (Hxi+Hyi)/2 was higher (P < 0.01) in the aneurysm tissues (1450 ± 250 kPa, mean ± SEM, n = 26) than in the undilated tissues (650 ± 140 kPa, n = 10). Anisotropy index K = |Hxi-Hyi|/Hmi was not significantly different between the aneurysm (20 ± 3%) and the undilated tissues (12 ± 3%) for all specimens. For the specimens whose elastic modulus Hmi was smaller than 1 MPa, however, the index K was significantly higher (P < 0.05) in the aneurysm specimens (23.1 ± 5.3%, n = 14) than the undilated tissues (9.5 ± 2.5%, n = 8). These results indicate aneurysm tissues are not only stiffer but also more anisotropic than the nonaneurysmal tissues.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080718115ZK.pdf 663KB PDF download
  文献评价指标  
  下载次数:28次 浏览次数:21次