期刊论文详细信息
Nanomaterials and Nanotechnology
Electrochemically Reduced Graphene Oxide-Nafion/Au Nanoparticle Modified Electrode for Hydrogen Peroxide Sensing
Yajie Lv1  Cheng-An Tao1  Jianfang Wang1  Fang Wang1  Hui Zhu1  Xiaorong Zou1 
关键词: Graphene;    Non-enzymatic Sensor;    Electrochemical;    Au Nanoparticles;    Hydrogen Peroxide;   
DOI  :  10.5772/63519
来源: InTech
PDF
【 摘 要 】

In this paper, a non-enzymatic hydrogen peroxide (H2O2) sensor, based on Au nanoparticles (AuNPs) electrodeposited on an electrochemically reduced graphene oxide(ERGO)-Nafion modified glass carbon electrode (GCE), was reported. The graphene oxide-(GO-)Nafion nanocomposites were first assembled on the GCE surface to produce a GO-Nafion electrode. GO was then electrochemically reduced to produce an ERGO-Nafion modified GCE (to be subsequently denoted as GCE/ERGO-Nafion). Afterwards, AuNPs were electrodeposited on the modified GCE to form a GCE/ERGO-Nafion/AuNPs electrode. The ERGO-Nafion nanocomposites and the electrodeposited AuNPs were characterized by infrared spectroscopy and scanning electron microscopy (SEM). The results showed that the GO was reduced successfully and the AuNPs were uniformly dispersed on the GCE/ERGO-Nafion electrode with a size of about 48nm. The cyclic voltammograms and the amperometric method were used to evaluate the electrocatalytic properties of the GCE/ERGO-Nafion/AuNPs electr...

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080717081ZK.pdf 1385KB PDF download
  文献评价指标  
  下载次数:19次 浏览次数:25次