期刊论文详细信息
Acoustical Science and Technology
Head movement during head-related transfer function measurements
Makoto Otani1  Hiroyuki Sagara2  Iwaki Toshima3  Tatsuya Hirahara1 
[1] Toyama Prefectural University;Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology;NTT Communication Science Laboratories
关键词: Head-related transfer function;    Head movement;   
DOI  :  10.1250/ast.31.165
学科分类:声学和超声波
来源: Acoustical Society of Japan
PDF
【 摘 要 】

References(20)Cited-By(2)In this work, head movements for three human subjects were measured simultaneously during head-related transfer function (HRTF) measurement for a period of 95 min each. The subjects’ heads moved in all directions during measurements. Excessive head movements were observed in the pitch and yaw directions. Head movements in the roll direction were small for all subjects. Specifically, the head position at the beginning and end of HRTF measurement differed by less than 1° in roll but by as much as 10° in pitch and yaw. Consequently, HRTFs for the front position measured at the beginning and the end of the measurement session differed by 4–6 dB in spectral distortion. These results reveal that when no head-support aids are used, HRTFs might contain large errors attributable to head movement.