期刊论文详细信息
Climate Research
Surface energy balance characteristics of a heterogeneous urban ballast facet
Wilhelm Kuttler1  Stephan Weber1 
关键词: Surface energy balance;    Ballast;    Osnabrück;    Thermal properties;    Energy balance closure;    Urban climate;   
DOI  :  10.3354/cr028257
来源: Inter-Research Science Publishing
PDF
【 摘 要 】
ABSTRACT: Surface energy balance measurements were conducted during a study period from June to September 2002 at a goods station in Osnabrück, Germany. The inner-urban facet with a surface area of 0.5 km2 was predominantly covered byballast. Turbulent latent and sensible heat fluxes were estimated by a modified Bowen ratio method; the ground heat flux was calculated from temperature gradients and a laboratory derived thermal conductivity. The thermal behaviour of the ballast facet incomparison to other urban surfaces is somewhat ‘two-sided’. Due to its thermal properties it behaves similarly to urban surfaces during the day, with high surface temperatures and large near-surface temperature amplitudes. About one-third of theincoming energy is converted into the turbulent sensible heat flux and 20% is converted into the ground heat flux. The latent heat flux at the site is of minor importance (16%). During the night, however, the thermal behaviour is more comparable to a‘rural-like’ surface than to an urban facet. The ballast surface cools significantly and the sensible heat flux is directed towards the surface. Due to the heterogeneity of the study site the energy balance shows a closure gap of around 30%.Reasons for the energy balance non-closure are discussed.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080705761ZK.pdf 2525KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:21次