期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Experimental Correlation of Mean Drop Size in Rotating Disc Contactors (RDC)
Yaser Ziaie-Shirkolaee1  Saeed Soltanali1 
[1] Department of Chemical Engineering, Faculty of Engineering, Tehran University
关键词: Drop Size;    Rotating Disc Contactor;    Hole Distributor;    Sauter Mean Diameter;   
DOI  :  10.1252/jcej.07WE265
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(49)Cited-By(5)A correlation of the average drop size in a rotating disc contractor is presented. The rotating disc contactors were studied under various conditions. Various items of importance are system physical properties, column geometry, disc speed and hole distributor diameter. Two systems water (continuous phase)/acetic acid/toluene (dispersed phase) and water (continuous phase)/succinic acid/n-butanol (dispersed phase) were used to give correlation. The correlation was fitted by software. The R-squared and Durbin-Watson state in this prediction are about 95% and 1.82, respectively. The average absolute value of the relative error, AARE, is about 2.2%.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080696286ZK.pdf 19KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:38次