期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Poor Fluidization Phenomena and Detection in the FBAC of the Tonghae CFB Boiler
Jae-Sung Kim1  Jong-Min Lee1  Dong-Won Kim1  Jong-Jin Kim1 
[1] Power Generation Laboratory, Korea Electric Power Research Institute
关键词: Poor Fluidization;    FBAC;    CFB;    Pressure Fluctuation;    Tonghae Boiler;   
DOI  :  10.1252/jcej.07WE098
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(7)Cited-By(2)Detection and clearance of poor fluidization in a simulated fluidized bed ash cooler were studied by analyzing the mixing properties of the bed materials and the pressure fluctuation of the air header distributor. We observed a bridge of large particles at the bed surface which caused the poor fluidization area to form at the entrance of the FBAC. The poor fluidization was caused not only by airflow rates but also by the particle discharge rates as well as particle size distribution in the FBAC. Additionally, we could easily detect the local poor fluidization through a simple method developed in the simulated FBAC and in the FBAC of the Tonghae CFB boiler. As local poor fluidization is detected, it should be possible to clear it up by regulating the flow rate of each air header in the FBAC.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080696266ZK.pdf 19KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:3次