Nobuhide Takahashi2  Akifusa Hagiwara3  Hidenori Kagamifuchi3  Koichi Yamada1  | |
[1] The University of Tokyo;Department of Fine Materials Engineering, Shinshu University;The Tokyo Electric Power Company, Inc. | |
关键词: SOFC Testing Device; CFD Analysis; Cell Performance; Heat and Mass Transfer; | |
DOI : 10.1252/jcej.07WE164 | |
来源: Maruzen Company Ltd | |
【 摘 要 】
References(4)A simulation model has been developed for the analysis of heat, flow and mass transfer coupled with the electrochemical reactions and current collection of a solid oxide fuel cell (SOFC) located in a double-tube type testing device. The simulation model was used to examine the influence of the current collection conditions and gas flow rates on the temperature and concentration fields in the device, and on the resulting cell performance. The results indicated that the high flow rate of air induced a great temperature gradient near the cell surface. It was also pointed out that the low flow rate of fuel significantly lowered the cell performance through the concentration field, especially when the flow channel for fuel gas was not enough long. The mathematical simulation of the phenomena occurring in the testing device as well as at the cell can be a strong measure for precise interpretation of the experimental results and the development of SOFCs.