Effects of Liquid Film Formed on Flask Surface on Oxygen Transfer Rate in Shaking Flask and Development of Baffled Shaking Vessel by Optical Method Based on Sulfite Oxidation | |
Young-Sei Lee2  Shuichi Iwata3  Yuichiro Nagatsu3  Yutaka Tada3  Song-Tae Koh1  Yoshihito Kato3  Eri Iwanaga3  | |
[1] Department of Chemical Engineering, Dongyang University;Department of Chemical Engineering, Sangju National University;Department of Applied Chemistry, Nagoya Institute of Technology | |
关键词: Mixing; Mass Transfer; Shaking Flask; Oxygen Transfer; Biochemical Engineering; | |
DOI : 10.1252/jcej.38.873 | |
来源: Maruzen Company Ltd | |
【 摘 要 】
References(6)Cited-By(6)The gas liquid mass transfer volumetric coefficients KLa in several kinds of small size shaking flasks were measured with an optical method based on sulfite oxidation without oxygen concentration probe and liquid sampling. It was found that the liquid film on the inner surface of a flask was one of the very important factors to increase KLa. The baffled flask was effective to obtain a larger oxygen transfer rate than the normal flask. A new developed baffled cylindrical vessel based on the baffled small flask has about three times larger KLa than the normal vessel.