期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN | |
Effect of Pellet Size on Discharge Characteristics of Latent Heat Storage Columns Packed with Cross-Linked Polymer Pellets | |
KOTARO TAGAWA1  KAZUYOSHI TANAKA1  YASUSHI KOITO1  OSAMU MIYATAKE1  YASUHIRO MARUTA1  | |
[1]Department of Chemical Engineering, Kyushu University | |
关键词: Heat Transfer; Latent Heat Storage; Cross-Linked Polymer Pellets; Experiment; Numerical Analysis; | |
DOI : 10.1252/jcej.34.819 | |
来源: Maruzen Company Ltd | |
【 摘 要 】
References(17)Experimental and numerical analyses are conducted to investigate the effect of the size of a formstable phase change material (FS-PCM) on discharge characteristics of packed-bed latent heat storage columns. Two types of cross-linked polymer pellets having different dimensions are used as the FS-PCM and water is used as the heat transfer fluid (HTF). Experimental results on the heat transfer in the packed bed of each FS-PCM and the discharge characteristics of the packed bed are reported. By using the empirical equations for estimating the heat transfer coefficient between the FS-PCM and the HTF obtained in the present experiment, the transient variation of the temperature of the HTF at the outlet of the packed bed is calcualted with a numerical method, and they agree with the experimental results under various operating conditions. It is also shown that by increasing the contact time between the FS-PCM and the HTF in the packed bed, the demerits caused by the thermal resistance in the FS-PCM and between the FS-PCM and the HTF are overcome.【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912080694933ZK.pdf | 19KB | download |