期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Particle Hold-up in Two Fluidized Reactor System with Two Loopseals
SUNG-HO CHO1  CHANG-KEUN YI1  JAE-EK SON1  DAL-HEE BAE1  DOWON SHUN1  GYOUNG-TAE JIN1 
[1] Korea Institute of Energy Research
关键词: Particle Hold-up;    Fluidized Reactor;    Loopseal;    Pressure Balance Curve;    Solid Circulation Rate;   
DOI  :  10.1252/jcej.34.269
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(6)Cited-By(2)Pressures in a circulation loop under various conditions were measured in a cold mode (a riser of 35 mm I.D.×5450 mm high and a fluidized reactor of 160 mm I.D.×1250 mm high) with particles of mean diameter of 78 μm, and bulk, and particle densities of 1.03, and 1.90 g/cm3, respectively. Solid circulation rates were measured with a load cell hopper. The particle hold-ups at various sections were analyzed from differential pressure data. The voidage in the riser reactor increases with the increase in gas velocity, even though the solid circulation rate increases with gas velocity. The solid circulation rate increases to a maximum with gas velocity at the riser, and levels off because the non-mechanical valve adopts the role of solid rate determing step in the circulation loop of the system. Particle hold-up in the riser reaction zone increases by using an underflow standpipe loopseal below the fluidized reactor instead of an overflow standpipe loopseal.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080694859ZK.pdf 19KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:9次