期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Overpotential Distribution for Nominally Monopolar Fluidized Bed Electrodes
J. K. Lee2  L. W. Shemilt3  H. S. Chun1 
[1] Department of Chemical Engineering, Korea University;Department of Environmental Engineering, National Fisheries University of Pusan;Department of Chemical Engineering, McMaster University
关键词: Fluidized Bed Electrode;    Macroscopic Model;    Charge Transfer Mechanism;    Overpotential Distribution;    Particle Aggregate;    Bipolarity;   
DOI  :  10.1252/jcej.28.25
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(12)Cited-By(1)A model has been developed for fluidized bed electrodes based on an operative bipolar mechanism and the concept of two bipolar aggregates of particles in the direction of current flow. Extensive measurements of local overpotential frequency distribution and time-averaged overpotentials using a probe electrode technique have been made in both monopolar and bipolar packed bed electrodes, and in both monopolar and bipolar fluidized bed electrodes. Validation of the probe for overpotential measurement is claimed; and good agreement between fluidized bed electrode measurements and the model has been shown. This validation of a reasonable model for bipolarity in fluidized bed electrodes should permit application in design and scale-up of such electrodes.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080693841ZK.pdf 790KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:5次