期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Ultrafiltration of Reverse Micelles Containing Enzyme
Kozo Nakamura1  Masaru Hakoda1 
[1] Department of Biological and Chemical Engineering, Gunma University
关键词: Lipase;    Aerosol OT;    Reverse Micelle;    Ultrafiltration;    Bioreactor;   
DOI  :  10.1252/jcej.28.14
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(18)Cited-By(2)The cross-flow ultrafiltration of reverse micelles was investigated to examine the applicability of a membrane reactor for continuous enzymatic reaction. An ultrafiltration ceramic membrane module of tubular type was used to separate the Aerosol OT reverse micelles from the continuous phase of iso-octane. The rejection of reverse micelles as well as the permeation flux were measured at different concentrations of surfactant, water, enzyme and molar ratio of water to surfactant ωo.The permeation flux decreased and the rejection of water increased with increase in the concentration of lipase, probably as a result of the higher enzyme mass adsorbed on the membrane. The rejection of reverse micelles also increased with increase in ωo, which influences the diameter of reverse micelle. The permeation flux, however, could not be correlated solely with the parameter ωo, and it depended on the concentration of surfactant itself when ωo was less than rive. This direct influence of surfactant is supposed to be due to the adsorption of surfactant in the membrane which can change the hydrophobic property of the membrane.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080693839ZK.pdf 779KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:22次