期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Modelling and Experimental Operation of a “Reverse-Rectification Column” for an Absorption Heat Pump
P. Le Goff1  H. Matsuda1  P.-M. Ranger1 
[1] Laboratoire des Sciences du Génie Chimique, C.N.R.S.-E.N.S.I.C.-I.N.P.L.
关键词: Absorption;    Absorption Heat Pump;    Heat Transformer;    Refrigeration;    Distillation;    Temperature Lift;   
DOI  :  10.1252/jcej.23.537
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(5)Cited-By(1)In a “reverse-rectification system,” a volatile liquid (water) is injected into the evaporator placed at the bottom of a packed column. A less-volatile liquid (ethylene glycol) is injected into the head of the column. In the column, vapor and liquid are contacted in countercurrent flow (glycol downfiow, water-vapor upflow). Some heat is evolved by the vapor-liquid absorption, and is extracted through a heat exchanger incorporated in the column.Three different structures of the system are modelled and compared, by using the Ponchon diagram.A lab-scale reverse-rectification column with an integrated glycol preheater was constructed and operated under atmospheric pressure.The measured performance criteria are: the temperature lift, which is the difference between the temperature of the upgraded heat flux extracted from the column and that of the heat flux supplied to the evaporator, and the heal efficiency, which is the ratio of these two heat fluxes.The temperature lift and the heat efficiency were studied as functions of the flow rates of the liquids injected at the top and the bottom of the system.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080693198ZK.pdf 1408KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:25次