JOURNAL OF CHEMICAL ENGINEERING OF JAPAN | |
Particle Holdup in a Fast Fluidized Bed | |
Cho Wang1  Takayuki Takarada1  Hideki Shibasaki1  Syunji Arita1  Kunio Kato1  Kazuhiko Tamura1  | |
[1] Department of Chemical Engineering, Gunma University | |
关键词: Fluidization; Fast Fluidized Bed; Chemical Reactor; Void Fraction; Particle Holdup; | |
DOI : 10.1252/jcej.22.130 | |
来源: Maruzen Company Ltd | |
【 摘 要 】
References(6)Cited-By(13)Particle holdup and axial pressure drop in a fast fluidized bed were measured. In a fast fluidized bed, there is a dense region of particles in the lower part of the bed and a dilute region of particles in the upper part of the bed. The height of the inflection point between the dense region of particles and the dilute region of particles was determined by an axial pressure drop profile. Its location was affected by the superficial gas velocity, the circulation rate of particles and the particle Reynolds number. An empirical equation for the location of the inflection point was obtained.Particle holdup in a fast fluidized bed was affected by superficial gas velocity, circulation rate of particles, particle Reynolds number, tube diameter, location of the inflection point and axial distance from the distributor. An empirical equation for particle holdup in a fast fluidized bed was obtained.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912080692993ZK.pdf | 1355KB | download |