| JOURNAL OF CHEMICAL ENGINEERING OF JAPAN | |
| Evaporation of Binary Solutions into Dry Air on a Vertical Flat Plate | |
| Tsutomu Ishikawa1  Shinichi Tanaka1  Koichi Asano1  Hitoshi Kosuge1  | |
| [1] Tokyo Institute of Technology | |
| 关键词: Evaporation; Heat Transfer; Mass Transfer; Diffusion Interaction; Ternary System; Vertical Flat Plate; Laminar Boundary Layer; Methanol 2-Propanol Air; Methanol Water Air; | |
| DOI : 10.1252/jcej.22.114 | |
| 来源: Maruzen Company Ltd | |
PDF
|
|
【 摘 要 】
References(18)Experimental approaches were taken to examine heat and mass transfer in evaporation of the methanol–2-propanol and the methanol–water systems into dry air by a cocurrent vertical flat-plate wetted-wall column over wide ranges of gas and liquid flow rates and liquid concentrations.The observed gas-phase sensible heat fluxes are compared with a theoretical analysis of heat transfer in a laminar boundary layer under high mass flux with finite tangential surface velocity. The effect of evaporative mass injection, tangential surface velocity and interactions between diffusion fluxes on the observed gas-phase diffusion fluxes are discussed. The observed diffusion fluxes are compared with a theoretical analysis of ternary mass transfer in a laminar boundary layer by taking into account the effect of interactions between diffusion fluxes under high mass flux with finite tangential surface velocity.