A correlation between femoral neck shaft angle to femoral neck length
Sanjay Vikani1  Jigna Parmar1  K V Bondre1  Subhash Moolchand Gujar1 
关键词: hip joint;    femoral neck shaft angle;    femoral neck length;    regression;    implant;   
DOI  :  10.7439/ijbar.v4i5.354
学科分类:药学、药理学、毒理学(综合)
来源: Scholar Science Journals
PDF
【 摘 要 】

Knowledge of the anatomy of proximal end of femur is a prerequisite for a complete understanding of the mechanics of the hip joint and serves as a basis for the treatment of pathological condition of the hip and femur. A total of 250 adult femora were used to? measure femoral neck shaft angle, femoral neck length & femoral total length at S.B.K.S Medical institute, Vadodara. The neck shaft angle range from 116 oto 150 owith means of 136.3 o& no significant side difference. The neck length range from 23mm to 44mm with mean of 34.4mm. The neck shaft angle significantly correlates with femoral neck length. The following is the regression equation : neck shaft angle = 95.28 o+ 1.20(length of neck). The present study is useful to remove lacuna of information about proximal femoral geometry in Indian people & calculate its impact on implant design. key words: .