Química Nova | |
Determination of anti-cancer drug emodin using a silica-gel-modified carbon paste electrode | |
Dilgin, Yusuf1  Ertek, Bensu1  University of Pardubice, Pardubice, Czech Republic1  Vu, Dai Long1  Cervenka, Libor1  University Hospital Hradec Kralove, Hradec Kralove, Czech Republic1  Canakkale Onsekiz Mart University, Canakkale, Turkey1  | |
关键词: emodin; carbon paste electrode; voltammetry.; | |
DOI : 10.5935/0100-4042.20140244 | |
学科分类:化学(综合) | |
来源: Sociedade Brasileira de Quimica | |
【 摘 要 】
In this paper, a silica-gel-modified carbon paste electrode (Si-gel/CPE) was used to determine the anti-cancer drug emodin by anodic stripping differential pulse voltammetry (ASDPV). The effects of the silica-gel content, the pH of the supporting electrolyte, and the scan rate on the oxidation current of emodin were investigated. The oxidation currents of emodin obtained from ASDPV measurements were linearly correlated with the concentration in the range of 5.0 × 10-9 to 300.0 × 10-9 mol L-1. The limit of detection was determined to be 1.5 × 10-9 mol L-1. The current method was successfully applied to determine emodin in a knotweed root sample, with recovery rate of 92.5% to 98.3%.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912050596185ZK.pdf | 226KB | download |