期刊论文详细信息
Química Nova
The constrution of a multi-cell galvanostatic equipament for accelerated stability electrode test
Solymossy, Victor1  Pereira, Ernesto Chaves1  Universidade Federal do Mato Grosso, Cuiabá, Brasil1  Universidade Federal de São Carlos, São Carlos, Brasil1  Terezo, Ailton José1 
关键词: accelerated stability test;    multi-cell;    equipment design.;   
DOI  :  10.1590/S0100-40422007000500049
学科分类:化学(综合)
来源: Sociedade Brasileira de Quimica
PDF
【 摘 要 】

The present work deals with the design and construction of an equipment for muti-cell accelerated stability test measurements (AST) of dimensionally stable anodes (DSA). The equipment was built using only components that were available in the laboratory. Measurements of three electrochemical cells can be performed using the developed software. The acquisition time interval and the cut-off potencial can be set by the user. Experimental data for RuO2 electrodes obtained with the built equipment are in agreement with the literature.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912050593897ZK.pdf 135KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:15次