期刊论文详细信息
Química Nova
Electroanalytical determination of 4-chilorophenol by square wave voltammetry on boron-doped diamond electrodes
Codognoto, Lúcia1  Avaca, Luis Alberto1  Pedrosa, Valber de Albuquerque1  Universidade de São Paulo, São Carlos1 
关键词: 4-chlorophenol;    square wave voltammetry;    diamond electrodes.;   
DOI  :  10.1590/S0100-40422003000600012
学科分类:化学(综合)
来源: Sociedade Brasileira de Quimica
PDF
【 摘 要 】

The anodic voltammetric behavior of 4-chlorophenol (4-CF) in aqueous solution has been studied on a Boron-doped diamond electrode using square wave voltammetry (SWV). After optimization of the experimental conditions, 4-CF was analyzed in pure and natural waters using a Britton-Robinson buffer with pH = 6.0 as the supporting electrolyte. Oxidation occurs at 0.80 V vs Ag/AgCl in a two-electron process controlled by adsorption of the species. The detection limits obtained were 6.4 µg L-1 in pure water and 21.5 µg L-1 for polluted water taken from a local creek, respectively. The combination of square wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912050593031ZK.pdf 308KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:9次