期刊论文详细信息
Journal of the Brazilian Chemical Society
Fast and simultaneous determination of Pb2+ and Cu2+ in water samples using a solid paraffin-based carbon paste electrode chemically modified with 2-aminothiazole-silica-gel
Santos, André L1  Silva, Daiane H1  Universidade Federal de Uberlândia, Ituiutaba, Brazil1  Takeuchi, Regina M1  Costa, Dayane A1 
关键词: anodic stripping voltammetry;    carbon paste electrode;    2 -aminothiazole-functionalized silica gel;    lead and copper determination;    water samples;   
DOI  :  10.1590/S0103-50532011000900015
学科分类:化学(综合)
来源: SciELO
PDF
【 摘 要 】

A solid paraffin-based carbon paste electrode modified with 2-aminothiazole functionalized silica-gel was used for simultaneous quantification of Pb2+ and Cu2+ in water samples by anodic stripping voltammetry. The present method uses short preconcentration time (180 s), which allowed reliable and simultaneous quantification of Pb2+ and Cu2+ in a very fast way. Detection limits of 7.3 and 90 nmol L-1 were obtained for Pb2+ and Cu2+, respectively. These values are below their maximum concentrations allowed in drinking water by Brazilian legislation, indicating that the proposed method is useful to monitoring Pb2+ and Cu2+ in water samples. Recovery studies were performed in four spiked water samples and the results shown recovery percentages close to 100% for all analyzed samples, demonstrating the good accuracy of the proposed method.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912050581430ZK.pdf 424KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:10次