Journal of the Brazilian Chemical Society | |
Application of a biomimetic sensor based on iron phthalocyanine chloride: 4-methylbenzylidene-camphor detection | |
Boni, Ana Carolina1  Sotomayor, Maria D. P. T.1  Universidade Federal do Maranhão, São Luís, Brazil1  Tanaka, Sônia Maria C. N.1  Universidade de São Paulo, São Carlos, Brazil1  Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, Brazil1  Lanza, Marcos R. V.1  Universidade Estadual Paulista, Araraquara, Brazil1  Tanaka, Auro A.1  | |
关键词: iron phthalocyanine; amperometric sensor; methylbenzylidene camphor; | |
DOI : 10.1590/S0103-50532010000700025 | |
学科分类:化学(综合) | |
来源: SciELO | |
【 摘 要 】
The construction and application of a biomimetic sensor for determination of 4-methylbenzylidene camphor (4-MBC), an ultraviolet (UV) radiation protector, are described. The sensor was prepared by modifying a carbon paste electrode with iron(III) phthalocyanine chloride (FePcCl). Amperometric measurements carried out with the sensor under an applied potential of 0.0 V vs. Ag|AgCl in a mixture of tetrahydrofuran and 0.1 mol L-1 H2SO4 solution (30:70 volume ratio) showed a linear response range from 1.8×10-4 to 9.0×10-4 mol L-1. A detailed selectivity investigation for other nine UV filters was also performed. A sensor response mechanism was proposed and the results for 4-MBC quantification in commercial sunscreens and in water from swimming pools and rivers are presented.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912050581066ZK.pdf | 236KB | download |