期刊论文详细信息
Ingeniería Electrónica, Automática y Comunicaciones
Una combinación de KICA y filtrado EWMA-ED para la detección de fallos de pequeña magnitud en procesos químicos
Bernal de Lázaro, José M.2  Silva Neto, Antônio J.1  Campos Knupp, Diego1  Prieto Moreno, Alberto2 
[1] Universidade do Estado do Rio de Janeiro UERJ, Brazil;CUJAE, La Habana, Cuba
关键词: Fault detection;    EWMA-ED;    Signal filtering;    Tennessee Eastman;    Hotelling T2.;   
DOI  :  
来源: Instituto Superior Politecnico "Jose Antonio Echeverria"
PDF
【 摘 要 】

The current industry requires of the fault diagnostic systems with a detection stage that can ensure a small number of false alarms and a quick detection of faults, regardless of their nature and magnitude. However, a common problem of the approaches based on the Multivariate Statistical Process Monitoring (MSPM) which are currently used for this purpose is the difficulty of them to detect small magnitude faults without incurring a high number of false alarms, and faults not detected. To overcome this drawback, in this paper is proposed a novel approach that combines the advantages of kernel methods, and a novel EWMA with enhanced dynamic to filter the T2 Hotelling statistic used as the fault detection mechanism in a complex chemical process.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912040556141ZK.pdf 912KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:28次