期刊论文详细信息
Pramana
Electron cyclotron resonance breakdown studies in a linear plasma system
D Bora1  K Sathyanarayana1  Vipin K Yadav1 21 
[1] Institute for Plasma Research, Bhat, Gandhinagar 382 428, India$$
关键词: Electron cyclotron resonance breakdown;    delay time;    e-folding time.;   
DOI  :  
学科分类:物理(综合)
来源: Indian Academy of Sciences
PDF
【 摘 要 】

Electron cyclotron resonance (ECR) plasma breakdown is studied in a small linear cylindrical system with four different gases - hydrogen, helium, argon and nitrogen. Microwave power in the experimental system is delivered by a magnetron at 2.45 ± 0.02 GHz in TE10 mode and launched radially to have extra-ordinary (X) wave in plasma. The axial magnetic field required for ECR in the system is such that the fundamental ECR surface (𝐵 = 875.0 G) resides at the geometrical centre of the plasma system. ECR breakdown parameters such as plasma delay time and plasma decay time from plasma density measurements are carried out at the centre using a Langmuir probe. The operating parameters such as working gas pressure (1 × 10-5 -1 × 10-2 mbar) and input microwave power (160{800 W) are varied and the corresponding effect on the breakdown parameters is studied. The experimental results obtained are presented in this paper.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912040497539ZK.pdf 229KB PDF download