期刊论文详细信息
Journal of Earth system science
Influence of epicentral distance on local seismic response in Kolkata City, India
Akhilesh K Verma11  Franco Vaccari2 32  Giuliano F Panza2 3 42  William K Mohanty11 
[1] Department of Geology and Geophysics, Indian Institute of Technology, Kharagpur 721 302, India.$$;Department of Mathematics and Geosciences, University of Trieste, Trieste, Italy.$$
关键词: Kolkata city;    response spectral ratio (RSR);    peak ground acceleration (PGA);    seismic sources;    hybrid technique.;   
DOI  :  
学科分类:天文学(综合)
来源: Indian Academy of Sciences
PDF
【 摘 要 】

The influence of source and epicentral distance on the local seismic response in the Kolkata city is investigated by computing the seismic ground motion along 2-D geological cross-sections in the Kolkata city for the earthquake that occurred on 12 June 1897 (𝑀𝑤 = 8.1; focal mechanism: dip = 57°, strike = 110° and rake = 76°; focal depth = 9 km) in Shillong plateau. For the estimation of ground motion parameters, a hybrid technique is used, which is the combination of modal summation and finite difference method. This technique allows the estimation of site specific ground motion for various events located at different distances from Kolkata city, taking into account simultaneously the position and geometry of the seismic source, the mechanical properties of the propagation medium and the geotechnical properties of the site. The epicenter of the Shillong earthquake is about 460 km away from Kolkata. The estimated peak ground acceleration (PGA) varies in the range of 0.11–0.18 g and this range corresponds to the intensity of IX to X on the Mercalli-Cancani-Sieberg (MCS) scale and VIII on the Modified Mercalli (MM) scale. The maximum amplification in terms of response spectral ratio (RSR) varies from 10 to 12 in the frequency range 1.0–1.5 Hz. These amplifications occur in correspondence to low-velocity shallow, loose soil deposit. The comparison of these results with earlier ones obtained considering the Calcutta earthquake that occurred on 15 April 1964 (𝑀𝑤 = 6.5; focal mechanism: dip = 32°, strike = 232° and rake = 56°; focal depth = 36 km) shows that the source parameters (magnitude and focal mechanism) and epicentral distance play an important role on site response but the variation in the frequency of the peak values (RSR) is negligible. The obtained results match with observed reported intensities in Kolkata region.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912040492418ZK.pdf 2930KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:2次