期刊论文详细信息
Proceedings of the International Conference on Coastal Engineering
COMPARISON OF PRESSURE AND STAFF WAVE GAGE RECORDS
D. Esteva1  D. Lee Harris1 
[1] U S Army Coastal Engineering Research Center
关键词: pressure gauge;    staff wave gauge;    gauge record;   
DOI  :  10.9753/icce.v12.%p
学科分类:建筑学
来源: Coastal Engineering Research Council
PDF
【 摘 要 】

Simultaneous records from two pressure gages located at different depths, a step-resistance relay gage, and a continuous-wire staff gage have been collected at Atlantic City, N J Spectra and cross-spectra are computed using the Fast Fourier Transform Algorithm (FFT) method proposed by Cooley and Tukey Individual harmonics of the pressure energy spectra are compensated for pressure attenuation according to classical theory Results indicate better agreement is obtained between the wave height and the spectra computed from the compensated pressure gages and those computed from the continuous-wire staff gage than between the two surface gages Values of coherences are near 98 in the energy-containing part of the spectrum, and are always larger for the pressure-continuous wire staff cases than for the two surface gages which are displaced from each other only 12 feet m the horizontal.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912020438480ZK.pdf 133KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:5次