Heron | |
Use of advanced corrosion monitoring for risk-based management of concrete structures | |
O. Klinghoffer1  R.B. Polder2  J. Leggedoor3  J. Eri4  W. Peelen2  | |
[1] 2 FORCE Technology, Brøndby, Denmark;1 TNO Built Environment and Geosciences, Delft, The Netherlands;4 Leggedoor Beton- & Vochtweringstechniek BV, Gasselternijveen, The Netherlands;3 Protector AS, Tranby, Norway | |
关键词: Concrete structures; reinforcement corrosion; monitoring; risk evaluation; management; | |
DOI : | |
学科分类:建筑学 | |
来源: Technische Universiteit Delft * Faculty of Civil Engineering | |
【 摘 要 】
Reinforced concrete is a cost effective material used widely in our infrastructure. The durable combination of steel and concrete provides safety and serviceability. Normally, the physics and chemistry of concrete protects reinforcing steel against corrosion. Over time this protection can be lost due to aggressiveness from the environment, for example chloride ions from seawater and de-icing salts, causing corrosion. Corrosion is the main cause of damage to concrete structures. Due to ageing of the infrastructure, maintenance costs have increased to a major part of the total costs. Proper management should include taking measures for repair and re-install corrosion protection before danger occurs.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912010227601ZK.pdf | 184KB | download |