期刊论文详细信息
Journal of Nuclear Medicine
Fetal and Maternal Absorbed Dose Estimates for Positron-Emitting Molecular Imaging Probes
Habib Zaidi1  Tianwu Xie1 
关键词: PET;    pregnant female model;    radiation dosimetry;    Monte Carlo;    simulation;   
DOI  :  10.2967/jnumed.114.141309
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

PET and hybrid (PET/CT and PET/MR) imaging currently play a pivotal role in clinical diagnosis, staging and restaging, treatment, and surveillance of several diseases. As such, limiting the radiation exposure of special patients, such as pregnant women, from PET procedures is an important challenge that needs to be appropriately addressed because of the high sensitivity of the developing embryo/fetus to ionizing radiation. Therefore, accurate radiation dose calculation for the embryo/fetus and pregnant patient from common positron-emitting radiotracers is highly desired. Methods: To obtain representative estimates of radiation dose to the human body, realistic biologic and physical models should be used. In this work, we evaluate the S values of 9 positron-emitting radionuclides (11C, 13N, 15O, 18F, 64Cu, 68Ga, 82Rb, 86Y, and 124I) and the absorbed and effective doses for 21 positron-emitting labeled radiotracers using realistic anthropomorphic computational phantoms of early pregnancy and at 3-, 6-, and 9-mo of gestation and the most recent biokinetic data available. The Monte Carlo N-Particle eXtended general-purpose Monte Carlo code was used for radiation transport simulation. Results: The absorbed dose to the pregnant model is less influenced by the gestation for most organs or tissues, but the anatomic changes of the maternal body increases the effective dose for some radiotracers. For 18F-FDG, the estimated absorbed doses to the embryo/fetus are 3.05E−02, 2.27E−02, 1.50E−02, and 1.33E−02 mGy/MBq at early pregnancy and 3-, 6-, and 9-mo gestation, respectively. The absorbed dose is nonuniformly distributed in the fetus and would be 1.03–2 times higher in the fetal brain than in other fetal soft tissues. Conclusion: The generated S values can be exploited to estimate the radiation dose delivered to pregnant patients and the embryo/fetus from various PET radiotracers used in clinical and research settings. The generated dosimetric database of radiotracers using new-generation computational models can be used for the assessment of radiation risks to pregnant women and the embryo/fetus undergoing PET/CT imaging procedures. This work also contributes to a better understanding of the absorbed dose distribution in the fetus.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010199281ZK.pdf 1636KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:5次