Journal of Nuclear Medicine | |
Cardiac Hypoxia Imaging: Second-Generation Analogues of 64Cu-ATSM | |
Erika Mariotti1  Gavin D. Kenny1  Philip J. Blower1  Ran Yan1  Maxwell G. Handley1  Richard Southworth1  Thomas R. Eykyn1  Karen P. Shaw1  Rodolfo A. Medina1  | |
[1] Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, United Kingdom Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, United Kingdom Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, United Kingdom | |
关键词: hypoxia; PET; 64Cu-ATSM; bis(thiosemicarbazones); 18FMISO; cardiac ischemia; | |
DOI : 10.2967/jnumed.113.129015 | |
学科分类:医学(综合) | |
来源: Society of Nuclear Medicine | |
【 摘 要 】
Myocardial hypoxia is an attractive target for diagnostic and prognostic imaging, but current approaches are insufficiently sensitive for clinical use. The PET tracer copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (64Cu-ATSM) has promise, but its selectivity and sensitivity could be improved by structural modification. We have therefore evaluated a range of 64Cu-ATSM analogs for imaging hypoxic myocardium. Methods: Isolated rat hearts (n = 5/group) were perfused with normoxic buffer for 30 min and then hypoxic buffer for 45 min within a custom-built triple-γ-detector system to quantify radiotracer infusion, hypoxia-dependent cardiac uptake, and washout. A 1-MBq bolus of each candidate tracer (and 18F-fluoromisonidazole for comparative purposes) was injected into the arterial line during normoxia, and during early and late hypoxia, and their hypoxia selectivity and pharmacokinetics were evaluated. The in vivo pharmacokinetics of promising candidates in healthy rats were then assessed by PET imaging and biodistribution. Results: All tested analogs exhibited hypoxia sensitivity within 5 min. Complexes less lipophilic than 64Cu-ATSM provided significant gains in hypoxic-to-normoxic contrast (14:1 for 64Cu-2,3-butanedione bis(thiosemicarbazone) (ATS), 17:1 for 64Cu-2,3-pentanedione bis(thiosemicarbazone) (CTS), 8:1 for 64Cu-ATSM, P < 0.05). Hypoxic first-pass uptake was 78.2% ± 7.2% for 64Cu-ATS and 70.7% ± 14.5% for 64Cu-CTS, compared with 63.9% ± 11.7% for 64Cu-ATSM. Cardiac retention of 18F-fluoromisonidazole increased from 0.44% ± 0.17% during normoxia to 2.24% ± 0.08% during hypoxia. In vivo, normoxic cardiac retention of 64Cu-CTS was significantly lower than that of 64Cu-ATSM and 64Cu-ATS (0.13% ± 0.02% vs. 0.25% ± 0.04% and 0.24% ± 0.03% injected dose, P < 0.05), with retention of all 3 tracers falling to less than 0.7% injected dose within 6 min. 64Cu-CTS also exhibited lower uptake in liver and lung. Conclusion: 64Cu-ATS and 64Cu-CTS exhibit better cardiac hypoxia selectivity and imaging characteristics than the current lead hypoxia tracers, 64Cu-ATSM and 18F-fluoromisonidazole.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912010199101ZK.pdf | 1057KB | download |