Journal of Nuclear Medicine
Assessment of Striatal Dopamine D2/D3 Receptor Availability with PET and 18F-Desmethoxyfallypride: Comparison of Imaging Protocols Suited for Clinical Routine
Philipp T. Meyer1  Bernhard Hellwig1  Timo S. Spehl1  Ursula Sahm1  Peter Reuland1  Wolfgang A. Weber1  Christian Winkler1  Florian Amtage1  Sabine Hellwig1  Cornelius Weiller1 
关键词: positron emission tomography;    dopamine receptor;    18F-DMPF;    kinetic modeling;    parkinsonism;   
DOI  :  10.2967/jnumed.112.103812
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Assessment of striatal dopamine receptor availability with 18F-desmethoxyfallypride PET is of high diagnostic utility in parkinsonism. The present study was undertaken to define the optimal clinical scan protocol with regard to quantification accuracy and scan time. Methods: Fourteen patients with parkinsonian syndromes underwent 18F-desmethoxyfallypride PET over 90 min. Volume-of-interest analyses were performed after spatial normalization, with the right and left caudate nuclei and putamina as target regions and the cerebellum as reference region. The estimate of target region binding potential (relative to nondisplaceable radioligand in tissue) (BPND) provided by the 2-step simplified reference tissue model (SRTM2) served as the reference standard. Additional analyses included the multilinear reference tissue model 2 (MRTM2), noninvasive graphical analyses, and single-scan analyses (peak-equilibrium analysis at 35–65 min [PEA]; pseudoequilibrium analysis at 60–90 min [PsEA]). Results: SRTM2 and MRTM2 yielded virtually identical results (mean BPND difference = 0.1% ± 0.5%, r2 = 1.0). Noninvasive graphical analyses with and without inclusion of the k2′ term were affected by a small BPND bias (2.5% ± 3.6% and −5.0% ± 6.7%, respectively), although correlations with SRTM2 were still excellent (r2 = 1.0 and 0.98, respectively). In turn, single-scan analyses suffered from limited precision (PEA, mean BPND bias = 0.7% ± 13.0%, r2 = 0.90) or a considerable positive bias (PsEA, 19.2% ± 7.1%, r2 = 0.98). Shortening scan time to 70 and 60 min resulted in an acceptable average BPND change (<5% decline) for SRTM2/MRTM2 and graphical analysis with inclusion of the k2′ term, respectively. Conclusion: Kinetic reference tissue model analyses of 18F-desmethoxyfallypride PET data offer the least biased results at a well-tolerable scan duration and should thus be pursued whenever possible. Single-scan analyses may be pragmatic alternatives that, however, suffer from a relevant positive bias (PsEA) or limited precision (PEA).

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010198267ZK.pdf 625KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:9次