Functional Imaging of Neuroendocrine Tumors: A Head-to-Head Comparison of Somatostatin Receptor Scintigraphy, 123I-MIBG Scintigraphy, and 18F-FDG PET
Ulrich Knigge1  Carsten Palnaes Hansen1  Andreas Kjaer1  Andreas Pfeifer1  Annika Loft1  Birgitte Federspiel1  Jann Mortensen1  Tina Binderup1  Liselotte Højgaard1 
关键词: neuroendocrine tumors;    somatostatin receptor scintigraphy;    123I-MIBG scintigraphy;    18F-FDG PET;   
DOI  :  10.2967/jnumed.109.069765
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Functional techniques are playing a pivotal role in the imaging of cancer today. Our aim was to compare, on a head-to-head basis, 3 functional imaging techniques in patients with histologically verified neuroendocrine tumors: somatostatin receptor scintigraphy (SRS) with 111In-diethylenetriaminepentaacetic acid-octreotide, scintigraphy with 123I-metaiodobenzylguanidine (MIBG), and 18F-FDG PET. Methods: Ninety-six prospectively enrolled patients with neuroendocrine tumors underwent SRS, 123I-MIBG scintigraphy, and 18F-FDG PET on average within 40 d. The functional images were fused with low-dose CT scans for anatomic localization, and the imaging results were compared with the proliferation index as determined by Ki67. Results: The overall sensitivity of SRS, 123I-MIBG scintigraphy, and 18F-FDG PET was 89%, 52%, and 58%, respectively. Of the 11 SRS-negative patients, 7 were 18F-FDG PET-positive, of which 3 were also 123I-MIBG scintigraphy–positive, giving a combined overall sensitivity of 96%. SRS also exceeded 123I-MIBG scintigraphy and 18F-FDG PET based on the number of lesions detected (393, 185, and 225, respectively) and tumor subtypes. 123I-MIBG scintigraphy was superior to 18F-FDG PET for ileal neuroendocrine tumors, and 18F-FDG PET was superior to 123I-MIBG scintigraphy for pancreaticoduodenal neuroendocrine tumors. The sensitivity of 18F-FDG PET (92%) exceeded that of both SRS (69%) and 123I-MIBG scintigraphy (46%) for tumors with a proliferation index above 15%. Conclusion: The overall sensitivity of 123I-MIBG scintigraphy and 18F-FDG PET was low compared with SRS. However, for tumors with a high proliferation rate, 18F-FDG PET had the highest sensitivity. The results indicate that, although SRS should still be the routine method, 18F-FDG PET provides complementary diagnostic information and is of value for neuroendocrine tumor patients with negative SRS findings or a high proliferation index.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010197745ZK.pdf 1404KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:13次