期刊论文详细信息
Journal of Nuclear Medicine
Cellular Dosimetry of 111In Using Monte Carlo N-Particle Computer Code: Comparison with Analytic Methods and Correlation with In Vitro Cytotoxicity
Conrad Chan1  Zhongli Cai1  Jean-Philippe Pignol1  Raymond M. Reilly1 
关键词: Monte Carlo dosimetry;    S-values;    Auger electrons;    breast cancer cells;    111In-DTPA-hEGF;    111In;   
DOI  :  10.2967/jnumed.109.063156
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Our objective was to compare Monte Carlo N-particle (MCNP) self- and cross-doses from 111In to the nucleus of breast cancer cells with doses calculated by reported analytic methods (Goddu et al. and Farragi et al.). A further objective was to determine whether the MCNP-predicted surviving fraction (SF) of breast cancer cells exposed in vitro to 111In-labeled diethylenetriaminepentaacetic acid human epidermal growth factor (111In-DTPA-hEGF) could accurately predict the experimentally determined values. Methods: MCNP was used to simulate the transport of electrons emitted by 111In from the cell surface, cytoplasm, or nucleus. The doses to the nucleus per decay (S values) were calculated for single cells, closely packed monolayer cells, or cell clusters. The cell and nucleus dimensions of 6 breast cancer cell lines were measured, and cell line–specific S values were calculated. Results: For self-doses, MCNP S values of nucleus to nucleus agreed very well with those of Goddu et al. (ratio of S values using analytic methods vs. MCNP = 0.962–0.995) and Faraggi et al. (ratio = 1.011–1.024). MCNP S values of cytoplasm and cell surface to nucleus compared fairly well with the reported values (ratio = 0.662–1.534 for Goddu et al.; 0.944–1.129 for Faraggi et al.). For cross doses, the S values to the nucleus were independent of 111In subcellular distribution but increased with cluster size. S values for monolayer cells were significantly different from those of single cells and cell clusters. The MCNP-predicted SF for monolayer MDA-MB-468, MDA-MB-231, and MCF-7 cells agreed with the experimental data (relative error of 3.1%, −1.0%, and 1.7%). The single-cell and cell cluster models were less accurate in predicting the SF. For MDA-MB-468 cells, relative error was 8.1% using the single-cell model and −54% to −67% using the cell cluster model. Individual cell-line dimensions had large effects on S values and were needed to estimate doses and SF accurately. Conclusion: MCNP simulation compared well with the reported analytic methods in the calculation of subcellular S values for single cells and cell clusters. Application of a monolayer model was most accurate in predicting the SF of breast cancer cells exposed in vitro to 111In-DTPA-hEGF.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010197698ZK.pdf 1537KB PDF download
  文献评价指标  
  下载次数:20次 浏览次数:11次