期刊论文详细信息
Journal of Nuclear Medicine
Contrast-Enhanced 18F-FDG PET/CT: 1-Stop-Shop Imaging for Assessing the Resectability of Pancreatic Cancer
Patrick Veit-Haibach1  Jan Soyka1  Stefan Heinrich1  Thomas F. Hany1  Ujwal Bhure1  Klaus Strobel1  Pierre-Alain Clavien1  Bernhard C. Pestalozzi1 
关键词: oncology;    PET/CT;    pancreatic cancer;    staging;    contrast enhancement;   
DOI  :  10.2967/jnumed.108.051466
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Patients with pancreatic cancer continue to have a poor prognosis, with a 5-y survival rate of less than 5%. Surgery is the only treatment that offers a potential cure. Determining resectability is the principal goal of staging in pancreatic cancer patients. Our objective was to evaluate the value of combined contrast-enhanced 18F-FDG PET/CT in assessing the resectability of pancreatic cancer and to compare enhanced PET/CT with the performance of PET alone and unenhanced PET/CT. Methods: Fifty patients (25 women and 25 men; mean age, 64.3 y; range, 39–84 y) with biopsy-proven pancreatic adenocarcinoma underwent enhanced 18F-FDG PET/CT for the evaluation of resectability. Criteria for unresectability were distant metastases, peritoneal carcinomatosis, arterial infiltration, or invasion of neighboring organs other than the duodenum. The performance of enhanced PET/CT regarding resectability was compared with that of PET alone and unenhanced PET/CT. Histology, intraoperative findings, and follow-up CT with clinical investigations were used as the reference standard. Results: According to the reference standard, 27 patients had disease that was not resectable because of distant metastases (n = 17), peritoneal carcinomatosis (n = 5), or local infiltration (n = 5). In the assessment of resectability, PET alone had a sensitivity of 100%, specificity of 44%, accuracy of 70%, positive predictive value of 61%, and negative predictive value of 100%; unenhanced PET/CT had respective values of 100%, 56%, 76%, 66%, and 100%; and enhanced PET/CT, 96%, 82%, 88%, 82%, and 96%. In 5 patients, unresectability was missed by all imaging methods and was diagnosed intraoperatively. Enhanced PET/CT was significantly superior to PET alone (P = 0.035), and there was a trend for enhanced PET/CT to be superior to unenhanced PET/CT (P = 0.070). Conclusion: The use of enhanced PET/CT as a 1-stop-shop imaging protocol for assessing the resectability of pancreatic cancer is feasible and accurate. Enhanced PET/CT is significantly superior to PET alone.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010197300ZK.pdf 887KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:11次