期刊论文详细信息
Journal of Nuclear Medicine
Voxel-Based Mouse and Rat Models for Internal Dose Calculations
Mary A. Emmons1  George E. Holburn1  Michael G. Stabin1  Todd E. Peterson1 
[1] Vanderbilt University, Nashville, Tennessee Vanderbilt University, Nashville, Tennessee Vanderbilt University, Nashville, Tennessee
关键词: radiobiology/dosimetry;    radionuclide therapy;    radiation safety;    animal models;    radiation effects;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

The ability to estimate absorbed doses in experimental animals to which radiolabeled material has been administered may be important in explaining and controlling potential radiation toxicity observed during preclinical trials. Most previously reported models for establishing doses to small animals have been stylized and mathematically based. This study establishes dose factors for internal sources in realistic models of a typical mouse and a typical rat, based on image data obtained using a dedicated small-animal CT scanner. Methods: A transgenic mouse (body mass, 27 g) and a Sprague–Dawley rat (body mass, 248 g) were imaged using the dedicated small-animal CT scanner. Identified organs were segmented using computer tools that Vanderbilt University applies to process human images for 3-dimensional dosimetry. Monte Carlo N-particle transport code (MCNP) input files were prepared from the 3-dimensional, voxel-based image data. Using methods established for human studies, radiation transport calculations of absorbed fractions (AFs) were performed using MCNP, version 4C, on the segmented images, and dose conversion factors for several radionuclides were developed. Results: AFs were established at discrete energies for electron and photon sources assumed to be uniformly distributed throughout approximately 10 source and target regions in both models. Electron self-irradiation AFs were significantly less than 1.0 for many organs, at energies above 0.5 MeV, and significant cross irradiation was observed for high-energy electrons, such as those from 90Y or 188Re, in many organs. Calculated dose conversion factors reflected these trends and agreed well with the results of other authors who have undertaken similar investigations. Conclusion: The AFs calculated in this study will be useful in determining the dose to organs for mice and rats similar in size to those studied here. The segmented, voxel-based models developed here can be used for external dose calculations as well.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010196582ZK.pdf 683KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:16次