期刊论文详细信息
Journal of Nuclear Medicine
18F-FET PET Compared with 18F-FDG PET and CT in Patients with Head and Neck Cancer
Andre Zimmermann1  Heinz H. Coenen1  Kurt Hamacher1  Jörn Risse1  Karl-Josef Langen1  Gabriele Stoffels1  Michael O. Flüss1  Dirk Pauleit1  Dagmar Bauer1 
关键词: 18F-FET;    18F-FDG;    head and neck cancer;    squamous cell carcinoma;    amino acids;    PET;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Recent studies suggest a somewhat selective uptake of O-(2-[18F]fluoroethyl)-l-tyrosine (FET) in cerebral gliomas and in squamous cell carcinoma (SCC) and a good distinction between tumor and inflammation. The aim of this study was to investigate the diagnostic potential of 18F-FET PET in patients with SCC of the head and neck region by comparing that tracer with 18F-FDG PET and CT. Methods: Twenty-one patients with suspected head and neck tumors underwent 18F-FET PET, 18F-FDG PET, and CT within 1 wk before operation. After coregistration, the images were evaluated by 3 independent observers and an ROC analysis was performed, with the histopathologic result used as a reference. Furthermore, the maximum standardized uptake values (SUVs) in the lesions were determined. Results: In 18 of 21 patients, histologic examination revealed SCC, and in 2 of these patients, a second SCC tumor was found at a different anatomic site. In 3 of 21 patients, inflammatory tissue and no tumor were identified. Eighteen of 20 SCC tumors were positive for both 18F-FDG uptake and 18F-FET uptake, one 0.3-cm SCC tumor was detected neither with 18F-FDG PET nor with 18F-FET PET, and one 0.7-cm SCC tumor in a 4.3-cm ulcer was overestimated as a 4-cm tumor on 18F-FDG PET and missed on 18F-FET PET. Inflammatory tissue was positive for 18F-FDG uptake (SUV, 3.7–4.7) but negative for 18F-FET uptake (SUV, 1.3–1.6). The SUVs of 18F-FDG in SCC were significantly higher (13.0 ± 9.3) than those of 18F-FET (4.4 ± 2.2). The ROC analysis showed significantly superior detection of SCC with 18F-FET PET or 18F-FDG PET than with CT. No significant difference (P = 0.71) was found between 18F-FDG PET and 18F-FET PET. The sensitivity of 18F-FDG PET was 93%, specificity was 79%, and accuracy was 83%. 18F-FET PET yielded a lower sensitivity of 75% but a substantially higher specificity of 95% (accuracy, 90%). Conclusion: 18F-FET may not replace 18F-FDG in the PET diagnostics of head and neck cancer but may be a helpful additional tool in selected patients, because 18F-FET PET might better differentiate tumor tissue from inflammatory tissue. The sensitivity of 18F-FET PET in SCC, however, was inferior to that of 18F-FDG PET because of lower SUVs.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010196524ZK.pdf 593KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:15次