期刊论文详细信息
Journal of Nuclear Medicine
Biodistribution and Radiation Dosimetry of the Serotonin Transporter Ligand 11C-DASB Determined from Human Whole-Body PET
Robert B. Innis1  Masanori Ichise1  Subroto Ghose1  Jeih-San Liow1  Jian-Qiang Lu1  Doug Vines1 
[1] Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
关键词: 11C-DASB;    serotonin transporter;    dosimetry;    whole-body biodistribution;    PET;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

11C-Labeled 3-amino-4-(2-dimethylaminomethylphenylsulfanyl)-benzonitrile (DASB) is a selective radioligand for the in vivo quantitation of serotonin transporters (SERTs) using PET. The goal of this study was to provide dosimetry estimates for 11C-DASB based on human whole-body PET. Methods: Dynamic whole-body PET scans were acquired for 7 subjects after the injection of 669 ± 97 MBq (18.1 ± 2.6 mCi) of 11C-DASB. The acquisition for each subject was obtained at 14 time points for a total of 115 min after injection of the radioligand. Regions of interest were placed over compressed planar images of source organs that could be visually identified to generate time–activity curves. Radiation burden to the body was calculated from residence times of these source organs using the MIRDOSE3.1 program. Results: The organs with high radiation burden included the lungs, urinary bladder wall, kidneys, gallbladder wall, heart wall, spleen, and liver. The activity peaked within 10 min after the injection of 11C-DASB for all these organs except twothe excretory organs gallbladder and urinary bladder wall, which had peak activities at 32 and 22 min, respectively. Monoexponential fitting of activity overlying the urinary bladder suggested that approximately 12% of activity was excreted via the urine. Simulations in which the urinary voiding interval was decreased from 4.8 to 0.6 h produced only modest effects on the dose to the urinary bladder wall. With a 2.4-h voiding interval, the calculated effective dose was 6.98 μGy/MBq (25.8 mrem/mCi). Conclusion: The estimated radiation burden of 11C-DASB is relatively modest and would allow multiple PET examinations of the same research subject per year.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010196025ZK.pdf 572KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:10次