期刊论文详细信息
Journal of Nuclear Medicine
CT Attenuation Correction for Myocardial Perfusion Quantification Using a PET/CT Hybrid Scanner
Christophe A. Wyss1  Gustav K. von Schulthess1  Mehdi Namdar1  Thomas F. Hany1  Alexander V. Konstantinidis1  Cyrill Burger1  Pascal Koepfli1  Thomas Berthold1  Philipp A. Kaufmann1 
关键词: hybrid PET/CT scanner;    CT attenuation correction;    myocardial blood flow;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

In routine PET, a 10- to 20-min transmission scan with a rotating 68Ge source is commonly obtained for attenuation correction (AC). AC is time-consuming using this procedure and could considerably be shortened by instead using a rapid CT scan. Our aim was to evaluate the feasibility of CT AC in quantitative myocardial perfusion PET using a hybrid PET/CT scanner. Methods: 13N-labeled NH3 and PET were used to measure myocardial blood flow (MBF) (mL/min/g) at rest and during standard adenosine stress. In group 1 (n = 7), CT scans (0.5 s) of the heart area with different tube currents (10, 40, 80, and 120 mA) were compared with a standard 68Ge transmission (20 min) and with no AC. In group 2 (n = 3), the repeatability of 8 consecutive CT scans at a tube current of 10 mA was assessed. In group 3 (n = 4), emission was preceded and followed by 3 CT scans (10 mA) and 1 68Ge scan for each patient. For reconstruction, filtered backprojection (FBP) was compared with iterative reconstruction (IT). Results: For group 1, no significant difference in mean MBF for resting and hyperemic scans was found when emission reconstructed with 68Ge AC was compared with emission reconstructed with CT AC at any of the different tube currents. Only emission without any correction differed significantly from 68Ge AC. For group 2, repeated measurements revealed a coefficient of variance ranging from 2% to 5% and from 2% to 6% at rest and at stress, respectively. For group 3, similar reproducibility coefficients (RC) for MBF were obtained when 68Ge ACFBP was compared with 68Ge ACIT (RC = 0.218) and when CT ACFBP was compared with CT ACIT (RC = 0.227). Even better reproducibility (lower RC) was found when 68Ge ACFBP was compared with CT ACFBP (RC = 0.130) and when 68Ge ACIT was compared with CT ACIT (RC = 0.146). Conclusion: Our study shows that for the assessment of qualitative and quantitative MBF with a hybrid PET/CT scanner, the use of CT AC (with a tube current of 10 mA) instead of 68Ge AC provides accurate results.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010195872ZK.pdf 608KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:9次