期刊论文详细信息
Journal of Nuclear Medicine
Assessment of Myocardial Reperfusion After Myocardial Infarction Using Automatic 3-Dimensional Quantification and Template Matching
Eva Evangelista1  Jean-Philippe Thirion1  Michel Meignan1  Jean Rosso1  Emmanuel Itti1  Jean-Luc Monin1  Gregory Klein1  Pascal Gueret1 
关键词: quantification;    coregistration;    myocardial perfusion;    myocardial infarction;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Assessment of perfusion defect extent is essential for determining prognosis after a myocardial infarction (MI), but quantification methods usually rely on segmental analysis, which may lack accuracy. We present an automated voxel-based and template-based approach for precise quantification of perfusion defect extent and reperfusion evolution. Methods: Coronary angiography and stress/reinjection 201Tl tomography were performed prospectively on 49 patients with recent MI (45 men; mean age ± SD, 54 ± 10 y), before and 3 mo after revascularization (40 angioplasties and 9 bypasses). Perfusion defect extent was quantified using expert 16-segment visual scoring of the slices and a 3-dimensional (3D) method with spatial normalization between times 1 and 2. Briefly, the latter automatically extracted myocardial edges, matched them to a reference template, and compared the perfusion intensity in each voxel with the intensity of the corresponding voxel in a control population of 100 healthy subjects. Results: Reocclusion occurred in 12 patients within 3 mo of surgery (all had undergone angioplasty). The perfusion gain between times 1 and 2, assessed by visual analysis, was significantly higher in permeable patients than in reoccluded patients: 12.4% ± 13.3% and 2.3% ± 8.2% of the initial stress defect, respectively (P = 0.02). Proportional gains, measured with the quantitative 3D method, were 4.5% ± 3.6% and 1.9% ± 2.7%, respectively (P = 0.02). Furthermore, the 3D method allowed measurement within the initial ischemic defect (reversible part of the stress defect at time 1), the extent of myocardium whose perfusion improved at time 2 (reperfusion), and the extent of myocardium whose perfusion remained unchanged (residual ischemia). A voxel-by-voxel analysis of these regions revealed that the proportion of reperfusion was significantly higher in permeable patients than in reoccluded patients: 60.0% ± 21.3% versus 40.0% ± 22.5%, respectively (P = 0.008). This was cumbersome to quantify using visual analysis and did not reach statistical significance, likely because of segmental division (partial-volume effect) and absence of spatial normalization. Conclusion: The 3D voxel-based quantification allows satisfying assessment of reperfusion 3 mo after MI. Moreover, the automated analysis using spatial normalization should facilitate a reproducible assessment of large populations over time.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010195788ZK.pdf 1077KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:4次