期刊论文详细信息
Journal of Nuclear Medicine
Use of a Dual-Head Coincidence Camera and 18F-FDG for Detection and Nodal Staging of Non-Small Cell Lung Cancer: Accuracy as Determined by 2 Independent Observers
John M.H. de Klerk1  Noël J.J. Schlösser1  Peter P. van Rijk1  Patricia F.A. Bakker1  Henk Stevens1 
关键词: non-small cell lung cancer;    18F-FDG;    dual-head coincidence camera;    interobserver variability;    mediastinal staging;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

The accurate detection of lung carcinoma and the determination of its stage remain significant clinical problems. 18F-FDG PET has been shown to improve detection and staging of lung cancer and to prevent unnecessary invasive procedures. Positron imaging with dual-head gamma cameras may not be as sensitive as PET, but recent studies have shown good results with these cameras. Methods: In the present study, we investigated 100 patients, 76 of whom were male and 24 female (mean age ± SD, 60.7 ± 9.4 y), with suspected non-small cell lung cancer. 18F-FDG scanning was performed using a dual-head coincidence camera 1 h after the intravenous injection of 185 MBq of 18F-FDG. For 46 patients, attenuation correction was also performed. Two independent observers unaware of clinical status analyzed all imaging studies. TNM classification was assigned after surgical staging. Results: In 44 patients with clinically suspected bronchogenic carcinoma, no evidence of malignancy was found. However, in 56 patients a pulmonary neoplasm was demonstrated. At interobserver analysis, a κ value of 0.94 (P < 0.0001) was found for detection of the primary tumor and a κ value of 0.63 (P < 0.0001) was found for mediastinal staging. A sensitivity of 96%, a specificity of 93%, and an accuracy of 95% were found for detection of pulmonary neoplasm. Assessment of lymph node involvement showed a sensitivity of 50%, a specificity of 92%, and an accuracy of 77%. The sensitivity of CT in assessing lymph node involvement was 36%, the specificity was 86%, and the accuracy was 67%. Attenuation correction provided more anatomic information, but no differences were seen between attenuation-corrected and non-attenuation-corrected images for detecting lesions or lymph node involvement. Conclusion: The present study confirms earlier data showing that 18F-FDG scans obtained with dual-head coincidence cameras are useful in the detection of non-small cell lung cancer and less suitable for staging of lymph node involvement, with accuracy comparable to that of CT.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010195500ZK.pdf 590KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:2次