期刊论文详细信息
Journal of Nuclear Medicine
99mTc-Sestamibi Retention Characteristics During Pharmacologic Hyperemia in Human Myocardium: Comparison with Coronary Flow Reserve Measured by Doppler Flowire
Hideaki Okazaki1  Susumu Fujino1  Norihisa Tonami1  Hisashi Bunko1  Kenichi Nakajima1  Ichiro Matsunari1  Junichi Taki1  Takashi Saga1 
[1] Department of Nuclear Medicine, Kanazawa University School of Medicine, Kanazawa; and Department of Cardiology, Fukui Prefectural Hospital, Fukui, Japan Department of Nuclear Medicine, Kanazawa University School of Medicine, Kanazawa; and Department of Cardiology, Fukui Prefectural Hospital, Fukui, Japan Department of Nuclear Medicine, Kanazawa University School of Medicine, Kanazawa; and Department of Cardiology, Fukui Prefectural Hospital, Fukui, Japan
关键词: 99mTc-sestamibi;    coronary flow reserve;    myocardial tracer retention;    pharmacologic hyperemia;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

The aim of the study was to investigate the increase in myocardial 99mTc-methoxyisobutylisonitrile (sestamibi) retention in humans during pharmacologic vasodilation. Methods: For calculation of the increase in 99mTc-sestamibi retention during hyperemia, baseline and adenosine triphosphate (ATP)–induced hyperemic stress sestamibi studies were performed using a same-day rest–stress protocol. On the injection of sestamibi, left ventricular dynamic data were obtained for 90 s. The increase in sestamibi retention from baseline to hyperemia was calculated by the formulawhere Cmh(t) and Cmb(t) are myocardial counts on the tomographic image, and Cbb(τ) and Cbh(τ) are the left ventricular blood-pool counts during the first transit of sestamibi at baseline and during hyperemia, respectively. Coronary flow increase during intravenous ATP stress was measured using intracoronary Doppler flow guide wire and compared with the scintigraphic results of 28 measurements in 22 patients. Results: Sestamibi retention increased as coronary flow velocity increased but plateaued at >2.5–3 times baseline flow velocity. The relationship between the increase in sestamibi retention (Y) and the increase in flow (X) is expressed as follows: Y = 0.44 + 0.60X − 0.068X2 (r = 0.82). Conclusion: In humans, the increase in 99mTc-sestamibi myocardial retention underestimates coronary flow reserve, particularly at high flow rates. Knowledge of these tracer retention characteristics will contribute to a more comprehensive understanding of the manner and interpretation of stress sestamibi imaging.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010194855ZK.pdf 708KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:11次