| Archives of Electrical Engineering | |
| Performance evaluation of fractional-slot tubular permanent magnet machines with low space harmonics | |
| Jiabin Wang1  | |
| 关键词: Linear machines; permanent magnet machines; | |
| DOI : 10.1515/aee-2015-0049 | |
| 来源: Versita | |
PDF
|
|
【 摘 要 】
This paper evaluates the perforamnce of fractional-slot per pole winding configurations for tubular permanent magnet (PM) machines that can effectively eliminate the most undesirable space harmonics in a simple and cost-effective manner. The benefits of the proposed machine topology winding configurations are illustrated through comparison with 9-slot, 10-pole tubular PM machine developed for a free piston energy converter under the same specification and volumetric constraints. It has been shown that the proposed machine topology results in more than 7 times reduction in the eddy current loss in the mover magnets and supporting tube, and hence avoids potential problem of excessive mover temperature and risk of demagnetization.
【 授权许可】
Unknown
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201912010188701ZK.pdf | 2517KB |
PDF