期刊论文详细信息
Journal of the Korean Chemical Society
Electrochemical Determination of L-Dopa Using Modified Electrodes with Ni(II)-Macrocyclic Complex
Ho-Sik Kim1  Hyung-Hwa Cho1  Seon-Yong Yi1  Zun-Ung Bae1 
关键词: L-Dopa;    Polymer Modified Electrode;    Ni(II)-Macrocyclic Complex;    Differential Pulse Voltammetry;   
DOI  :  
学科分类:化学(综合)
来源: Korean Chemical Society
PDF
【 摘 要 】

The polymer modified electrode was manufactured by a cyclic voltammetric method using a synthesized Ni(II) complex with dianionic benzoN4 macrocycle. The electrocatalytic characteristics for the oxidation of L-Dopa at a polymer modified electrode was studied by cyclic voltammetry. The results showed that the oxidation peak potential was shifted to the lower potential and the oxidation peak current was increased in comparison with the unmodified electrode. The optimal experimental conditions for the voltammetric determination of L-Dopa were as follows: pH, 7.4; temperature, 35oC; the number of scan for modification by cyclic voltammetry, 1; preconcentration time, 90s. The polymer modified electrode was stable to determine L-Dopa for more than 2 months. The calibration curve for L-Dopa that linear range is 6.0 10-7 M~4.0 10-4 M, the correlation coefficient is 0.996, and the detection limit is 9.0 10-8 M. The effects of interferences were studied for 27 candidates which might exist in biological samples all the species except dopamine did not interfere the determination of L-Dopa.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010187358ZK.pdf 1108KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:12次