期刊论文详细信息
Defence Science Journal
Effects of Ultrasound Power, Temperature and Flow Rate of Solvent on Decontamination of Sensitive Equipment by Extraction
František Opluštil2  Josef Čáslavský1  Marek Andrle2 
[1] Brno University of Technology, Purkyňova;Military Research Institute Brno, Veslařská
关键词: Chemical warfare agents;    decontamination;    sensitive equipment;    extraction;   
DOI  :  
学科分类:社会科学、人文和艺术(综合)
来源: Defence Scientific Information & Documentation Centre
PDF
【 摘 要 】

The solvent extraction process is regarded amongst other known methods to be applicable for decontamination of sensitive equipment components, especially in cases the components are contaminated in-depth with chemical warfare agents. Viability of the solvent extraction method was evaluated on coupons of butadiene rubber contaminated by sulphur mustard before decontamination by the solvent extraction. The contaminated coupons were extracted in a flow cell, which the solvent (ethoxynonafluorobutane) passed through. Three following specific operational factors, namely the temperature, the flow rate, and the power of ultrasound bath, were assessed for the extent of influencing upon the respective observed extraction efficiencies. The paper describes the results of the evaluation of the solvent extraction effectiveness. Defence Science Journal, 2014, 64(2), pp. 168-172.  DOI: http://dx.doi.org/10.14429/dsj.64.3887

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010140549ZK.pdf 439KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:10次