期刊论文详细信息
| Defence Science Journal | |
| A PC- Based Transient Method for Thermal Conductivity Measurement. | |
| A.K. Singh1  | |
| [1] Institute of Armament Technology, Pune | |
| 关键词: Propellant oxidisers; Thermal conductivity; Automated measurements; Thermal probes; | |
| DOI : | |
| 学科分类:社会科学、人文和艺术(综合) | |
| 来源: Defence Scientific Information & Documentation Centre | |
PDF
|
|
【 摘 要 】
In this paper, an indigenously developed thermal probe has been interfaced with a PC for automated measurement of thermal conductivity (K ). The developed system has been calibrated and standardised by measuring K of glycerol. The maximum percentage error, for repeated sets of observations, was within 7.29 per cent of standard value reported for glycerol. This methodology has been successfully employed for measuring K of propellant oxidisers, additives, binders, etc.
【 授权许可】
Unknown
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201912010140422ZK.pdf | 859KB |
PDF