期刊论文详细信息
Defence Science Journal
Reliability Demonstration of Safety Actuating Mechanism
S.S. Panwar1 
[1] Defence Research & Development Laboratory, Hyderabad
关键词: Weapon systems;    Single shot airborne systemsAbstract : ";    Development of high technology and high cost weapo;   
DOI  :  
学科分类:社会科学、人文和艺术(综合)
来源: Defence Scientific Information & Documentation Centre
PDF
【 摘 要 】

Development of high technology and high cost weapons system is a difficult task in view of. highreliability goals. It is further compounded in the case of single-shot airborne systems. Overall reliabilityof weapons system depends upon the reliability of systems and sub-systems used. Design of each systemand sub-system is fmalised after preliminary design review, critical design review, etc. and final reliabilityis demonstrated by subeing to functional tests.Warhead is the only sub-system responsible for inflicting damage to the target and all the otherembsystemsassist in delivering the warhead on or near the target. Safety actuating mechanism (SAM) subsystemis a single-shot device which provides safety during handling, launch and flight of a missile and actuatesthe warhead, whenever desired on receipt of firing pulse from radio altitude switch. SAM being critical forsuccessful detonation of the warhead, it is desired that this unit should have very high reliability. SAMunits are subjected to reliability tests and a reliability factor of 0.84 at 90 per cent confidence level is achievedwhich further increases to 0.98 due to redundancy.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010140374ZK.pdf 611KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:15次